Mercurial > repos > devteam > picard1106
view AddOrReplaceReadGroups.xml @ 153:5d881472c379 draft default tip
mm
author | Rayan Chikhi <chikhi@psu.edu> |
---|---|
date | Mon, 21 Jul 2014 16:36:03 -0400 |
parents | d0c2cba2bdce |
children |
line wrap: on
line source
<tool name="Add or Replace Groups" id="picard_ARRG" version="1.106.0"> <description>Replaces all read groups</description> <requirements><requirement type="package" version="1.106.0">picard</requirement></requirements> <command interpreter="bash"> simple_wrapper.sh AddOrReplaceReadGroups.jar INPUT="${inputFile}" RGLB="${rglb}" RGPL="${rgpl}" RGPU="${rgpu}" RGSM="${rgsm}" RGID="${rgid}" #if $readGroupOpts.rgOpts == "full" RGCN="${readGroupOpts.rgcn}" RGDS="${readGroupOpts.rgds}" RGPI="${readGroupOpts.rgpi}" #end if #if $reporting.opt == "full" VALIDATION_STRINGENCY="${reporting.vs}" QUIET="${reporting.verbosity}" #else VALIDATION_STRINGENCY=LENIENT QUIET=True #end if OUTPUT="${outFile}" TMP_DIR="${__new_file_path__}" </command> <stdio> <exit_code range="0" level="warning" description="Tool finished correctly" /> </stdio> <inputs> <param format="bam,sam" name="inputFile" type="data" label="SAM/BAM dataset to add or replace read groups in" help="If empty, upload or import a SAM/BAM dataset." /> <param name="rgid" value="1" type="text" label="Read group ID (ID tag)" help="The most important read group tag. Galaxy will use a value of '1' if nothing provided." /> <param name="rgsm" value="" type="text" label="Read group sample name (SM tag). Required." /> <param name="rglb" value="" type="text" label="Read group library (LB tag). Required." /> <param name="rgpl" value="Illumina" type="text" label="Read group platform (PL tag). Required." help="illumina, solid, 454, pacbio, helicos" /> <param name="rgpu" value="" type="text" label="Read group platform unit. Required." help="like run barcode, etc." /> <conditional name="readGroupOpts"> <param name="rgOpts" type="select" label="Specify additional (optional) arguments" help="Allows you to set GCN, RGDS, and RGPI"> <option value="preSet">Use pre-set defaults</option> <option value="full">Set optional arguments</option> </param> <when value="preSet" /> <when value="full"> <param name="rgcn" value="" type="text" label="Read group sequencing center name" help="Leave set to <null> for default (none)" /> <param name="rgds" value="" type="text" label="Read group description" help="Leave set to <null> for default (none)" /> <param name="rgpi" value="" type="text" label="Predicted insert size" help="Leave set to <null> for default (none)" /> </when> </conditional> <conditional name="reporting"> <param name="opt" type="select" label="Change reporting options" help="Allows you to set Validation Stringency and Verbosity"> <option value="preSet">Use pre-set defaults</option> <option value="full">Set optional arguments</option> </param> <when value="preSet" /> <when value="full"> <param name="vs" type="select" label="Set validation stringency"> <option value="LENIENT" selected="True">Lenient</option> <option value="STRICT">Strict</option> <option value="SILENT">Silent</option> </param> <param name="verbosity" type="select" label="Enable or supress reporting of job summary to Standard Error"> <option value="True" selected="True">Supress</option> <option value="False">Enable</option> </param> </when> </conditional> </inputs> <outputs> <data name="outFile" format="bam"> </data> </outputs> <tests> <test> <!-- Command for replacing read groups in bam: java -jar AddOrReplaceReadGroups.jar VALIDATION_STRINGENCY=LENIENT INPUT=./test-data/PICARD-in-noHeader.sam OUTPUT=./test-data/PICARD-ARRG-test1.bam RGLB=test1 RGPL=Illumina RGPU=PLAT RGSM=sample1 RGID=test1 QUIET=True --> <param name="inputFile" value="PICARD-in-noHeader.sam" /> <param name="rglb" value="test1" /> <param name="rgpl" value="Illumina" /> <param name="rgpu" value="PLAT" /> <param name="rgsm" value="sample1" /> <param name="rgid" value="test1" /> <param name="rgOpts" value="preSet" /> <param name="opt" value="preSet" /> <output name="outFile" file="PICARD-ARRG-test1.bam" lines_diff="2" ftype="bam" /> </test> <test> <!-- Command for replacing read groups in sam: java -jar AddOrReplaceReadGroups.jar VALIDATION_STRINGENCY=LENIENT INPUT=./test-data/in.sam OUTPUT=./test-data/PICARD-ARRG-test2.bam RGLB=test2 RGPL=Illumina RGPU=PLAT RGSM=sample2 RGID=test2 QUIET=True picard_ARRG_input1.bam can be created from picard_ARRG_input1.sam --> <param name="inputFile" value="PICARD-in.sam" /> <param name="rglb" value="test2" /> <param name="rgpl" value="Illumina" /> <param name="rgpu" value="PLAT" /> <param name="rgsm" value="sample2" /> <param name="rgid" value="test2" /> <param name="rgOpts" value="preSet" /> <param name="opt" value="preSet" /> <output name="outFile" file="PICARD-ARRG-test2.bam" lines_diff="2" ftype="bam" /> </test> <test> <!-- Command for adding read groups in sam: java -jar AddOrReplaceReadGroups.jar VALIDATION_STRINGENCY=LENIENT INPUT=./test-data/in.bam OUTPUT=./test-data/PICARD-ARRG-test3.bam RGLB=test3 RGPL=Illumina RGPU=PLAT RGSM=sample3 RGID=test3 QUIET=True --> <param name="inputFile" value="PICARD-in.bam" /> <param name="rglb" value="test3" /> <param name="rgpl" value="Illumina" /> <param name="rgpu" value="PLAT" /> <param name="rgsm" value="sample3" /> <param name="rgid" value="test3" /> <param name="rgOpts" value="preSet" /> <param name="opt" value="preSet" /> <output name="outFile" file="PICARD-ARRG-test3.bam" lines_diff="2" ftype="bam" /> </test> </tests> <help> .. class:: infomark **Purpose** Add or Replace Read Groups in an input BAM or SAM file. **Read Groups are Important!** Setting read groups correctly from the start will simplify your life greatly because you can merge multiple BAM files into one significantly reducing the number of analysis steps. Below we provide an explanation of read groups fields taken from GATK FAQ webpage: .. csv-table:: :header-rows: 1 Tag,Importance,Definition,Meaning "ID","Required","Read group identifier. Each @RG line must have a unique ID. The value of ID is used in the RG tags of alignment records. Must be unique among all read groups in header section. Read group IDs may be modified when merging SAM files in order to handle collisions.","Ideally, this should be a globally unique identify across all sequencing data in the world, such as the Illumina flowcell + lane name and number. Will be referenced by each read with the RG:Z field, allowing tools to determine the read group information associated with each read, including the sample from which the read came. Also, a read group is effectively treated as a separate run of the NGS instrument in tools like base quality score recalibration (a GATK component) -- all reads within a read group are assumed to come from the same instrument run and to therefore share the same error model." "SM","Sample. Use pool name where a pool is being sequenced.","Required. As important as ID.","The name of the sample sequenced in this read group. GATK tools treat all read groups with the same SM value as containing sequencing data for the same sample. Therefore it's critical that the SM field be correctly specified, especially when using multi-sample tools like the Unified Genotyper (a GATK component)." "PL","Platform/technology used to produce the read. Valid values: ILLUMINA, SOLID, LS454, HELICOS and PACBIO.","Important. Not currently used in the GATK, but was in the past, and may return. The only way to known the sequencing technology used to generate the sequencing data","It's a good idea to use this field." "LB","DNA preparation library identify","Essential for MarkDuplicates","MarkDuplicates uses the LB field to determine which read groups might contain molecular duplicates, in case the same DNA library was sequenced on multiple lanes." **Example of Read Group usage** Support we have a trio of samples: MOM, DAD, and KID. Each has two DNA libraries prepared, one with 400 bp inserts and another with 200 bp inserts. Each of these libraries is run on two lanes of an illumina hiseq, requiring 3 x 2 x 2 = 12 lanes of data. When the data come off the sequencer, we would create 12 BAM files, with the following @RG fields in the header:: Dad's data: @RG ID:FLOWCELL1.LANE1 PL:illumina LB:LIB-DAD-1 SM:DAD PI:200 @RG ID:FLOWCELL1.LANE2 PL:illumina LB:LIB-DAD-1 SM:DAD PI:200 @RG ID:FLOWCELL1.LANE3 PL:illumina LB:LIB-DAD-2 SM:DAD PI:400 @RG ID:FLOWCELL1.LANE4 PL:illumina LB:LIB-DAD-2 SM:DAD PI:400 Mom's data: @RG ID:FLOWCELL1.LANE5 PL:illumina LB:LIB-MOM-1 SM:MOM PI:200 @RG ID:FLOWCELL1.LANE6 PL:illumina LB:LIB-MOM-1 SM:MOM PI:200 @RG ID:FLOWCELL1.LANE7 PL:illumina LB:LIB-MOM-2 SM:MOM PI:400 @RG ID:FLOWCELL1.LANE8 PL:illumina LB:LIB-MOM-2 SM:MOM PI:400 Kid's data: @RG ID:FLOWCELL2.LANE1 PL:illumina LB:LIB-KID-1 SM:KID PI:200 @RG ID:FLOWCELL2.LANE2 PL:illumina LB:LIB-KID-1 SM:KID PI:200 @RG ID:FLOWCELL2.LANE3 PL:illumina LB:LIB-KID-2 SM:KID PI:400 @RG ID:FLOWCELL2.LANE4 PL:illumina LB:LIB-KID-2 SM:KID PI:400 Note the hierarchical relationship between read groups (unique for each lane) to libraries (sequenced on two lanes) and samples (across four lanes, two lanes for each library). **Picard documentation** This is a Galaxy wrapper for AddOrReplaceReadGroups, a part of the external package Picard-tools_. .. _Picard-tools: http://www.google.com/search?q=picard+samtools ------ .. class:: infomark **Inputs, outputs, and parameters** Either a sam file or a bam file must be supplied. If a bam file is used, it must be coordinate-sorted. Galaxy currently coordinate-sorts all bam files. The output file is either bam (the default) or sam, according to user selection, and contains the same information as the input file except for the appropraite additional (or modified) read group tags. Bam is recommended since it is smaller. From the Picard documentation. AddOrReplaceReadGroups REQUIRED parameters:: Option (Type) Description RGLB=String Read Group Library RGPL=String Read Group platform (e.g. illumina, solid) RGPU=String Read Group platform unit (eg. run barcode) RGSM=String Read Group sample name RGID=String Read Group ID; Default value: null (empty) AddOrReplaceReadGroups OPTIONAL parameters:: Option (Type) Description RGCN=String Read Group sequencing center name; Default value: null (empty) RGDS=String Read Group description Default value: null (empty) AddOrReplaceReadGroups REPORTING parameters:: Option (Type) Description VALIDATION_STRINGENCY=ValidationStringency Validation stringency for all SAM files read by this program. Setting stringency to SILENT can improve performance when processing a BAM file in which variable-length data (read, qualities, tags) do not otherwise need to be decoded. Default value (in Galaxy): LENIENT. QUIET=Boolean Whether to suppress job-summary info on System.err. Default value (in Galaxy): True. .. class:: warningmark **Warning on SAM/BAM quality** Many SAM/BAM files produced externally and uploaded to Galaxy do not fully conform to SAM/BAM specifications. Galaxy deals with this by using the **LENIENT** flag when it runs Picard, which allows reads to be discarded if they're empty or don't map. This appears to be the only way to deal with SAM/BAM that cannot be parsed. </help> </tool>