diff macros.xml @ 0:fe1f0f16d9e6 draft

planemo upload for repository https://github.com/workflow4metabolomics/xcms commit cfb08142b6bfb78002b4e0d7775adb1a58e66c33-dirty
author lecorguille
date Thu, 08 Mar 2018 02:48:44 -0500
parents
children e6fdadaf039e
line wrap: on
line diff
--- /dev/null	Thu Jan 01 00:00:00 1970 +0000
+++ b/macros.xml	Thu Mar 08 02:48:44 2018 -0500
@@ -0,0 +1,191 @@
+<?xml version="1.0"?>
+<macros>
+    <token name="@WRAPPER_VERSION@">3.0.0</token>
+    <xml name="requirements">
+        <requirements>
+            <requirement type="package" version="@WRAPPER_VERSION@">bioconductor-xcms</requirement>
+            <requirement type="package" version="1.1_4">r-batch</requirement>
+            <requirement type="package" version="1.1_2">r-rcolorbrewer</requirement>
+            <requirement type="package" version="6.0">unzip</requirement>
+            <yield />
+        </requirements>
+    </xml>
+    <xml name="stdio">
+        <stdio>
+            <exit_code range="1" level="fatal" />
+        </stdio>
+    </xml>
+
+    <token name="@COMMAND_XCMS_SCRIPT@">LC_ALL=C Rscript $__tool_directory__/</token>
+
+    <token name="@COMMAND_LOG_EXIT@">
+        ;
+        return=\$?;
+        cat 'log.txt';
+        sh -c "exit \$return"
+    </token>
+
+    <xml name="input_validator_range_integer">
+        <validator type="regex" message="The format is 'min,max'" >[0-9]+ *, *[0-9]+</validator>
+    </xml>
+
+    <xml name="input_validator_range_float">
+        <validator type="regex" message="The format is 'min,max'" >[0-9]+\.?[0-9]* *, *[0-9]+\.?[0-9]*</validator>
+    </xml>
+
+    <xml name="input_validator_list_integer">
+        <validator type="regex" message="The format is '1,2,4,6'" >[0-9, ]+</validator>
+    </xml>
+
+    <token name="@INPUT_IMAGE_LABEL@">RData file</token>
+    <token name="@INPUT_IMAGE_HELP@">It contain a xcms3::XCMSnExp object (named xdata)</token>
+
+    <!-- zipfile load for planemo test -->
+
+    <token name="@COMMAND_FILE_LOAD@">
+        #if $file_load_section.file_load_conditional.file_load_select == "yes":
+            #if $file_load_section.file_load_conditional.input[0].is_of_type("mzxml") or $file_load_section.file_load_conditional.input[0].is_of_type("mzml") or $file_load_section.file_load_conditional.input[0].is_of_type("mzdata") or $file_load_section.file_load_conditional.input[0].is_of_type("netcdf"):
+                #set singlefile_galaxyPath = '|'.join( [ str( $single_file ) for $single_file in $file_load_section.file_load_conditional.input ] )
+                #set singlefile_sampleName = '|'.join( [ str( $single_file.name ) for $single_file in $file_load_section.file_load_conditional.input ] )
+
+                singlefile_galaxyPath '$singlefile_galaxyPath' singlefile_sampleName '$singlefile_sampleName'
+            #else
+                zipfile '$file_load_section.file_load_conditional.input'
+            #end if
+        #end if
+    </token>
+
+    <xml name="input_file_load">
+        <section name="file_load_section" title="Resubmit your raw dataset or your zip file">
+            <conditional name="file_load_conditional">
+                <param name="file_load_select" type="select" label="Resubmit your dataset or your zip file" help="Use only if you get a message which say that your original dataset or zip file have been deleted on the server." >
+                    <option value="no" >no need</option>
+                    <option value="yes" >yes</option>
+                </param>
+                <when value="no">
+                </when>
+                <when value="yes">
+                    <param name="input" type="data" format="mzxml,mzml,mzdata,netcdf,no_unzip.zip,zip" multiple="true" label="File(s) from your history containing your chromatograms" help="Single file mode for the format: mzxml, mzml, mzdata and netcdf. Zip file mode for the format: no_unzip.zip, zip. See the help section below." />
+                </when>
+            </conditional>
+        </section>
+    </xml>
+
+    <xml name="test_file_load_zip">
+        <section name="file_load_section">
+            <conditional name="file_load_conditional">
+                <param name="file_load_select" value="yes" />
+                <param name="input" value="faahKO_reduce.zip" ftype="zip" />
+            </conditional>
+        </section>
+    </xml>
+
+    <xml name="test_file_load_zip_sacuri">
+        <section name="file_load_section">
+            <conditional name="file_load_conditional">
+                <param name="file_load_select" value="yes" />
+                <param name="input" value="sacuri_dir_root.zip" ftype="zip" />
+            </conditional>
+        </section>
+    </xml>
+
+    <xml name="test_file_load_single">
+        <section name="file_load_section">
+            <conditional name="file_load_conditional">
+                <param name="file_load_select" value="yes" />
+                <param name="input" value="wt15.CDF,ko16.CDF,ko15.CDF,wt16.CDF" ftype="netcdf" />
+            </conditional>
+        </section>
+    </xml>
+
+    <token name="@COMMAND_PEAKLIST@">
+        #if $peaklist.peaklistBool
+            convertRTMinute $peaklist.convertRTMinute
+            numDigitsMZ $peaklist.numDigitsMZ
+            numDigitsRT $peaklist.numDigitsRT
+            intval $peaklist.intval
+        #end if
+    </token>
+
+    <xml name="input_peaklist">
+        <conditional name="peaklist">
+            <param name="peaklistBool" type="boolean" label="Get a Peak List" />
+            <when value="true">
+              <param name="convertRTMinute" type="boolean" checked="false" truevalue="TRUE" falsevalue="FALSE" label="Convert retention time (seconds) into minutes" help="Convert the columns rtmed, rtmin and rtmax into minutes"/>
+              <param name="numDigitsMZ" type="integer" value="4" label="Number of decimal places for mass values reported in ions' identifiers." help="A minimum of 4 decimal places is recommended. Useful to avoid duplicates within identifiers" />
+              <param name="numDigitsRT" type="integer" value="0" label="Number of decimal places for retention time values reported in ions' identifiers." help="Useful to avoid duplicates within identifiers" />
+              <param name="intval" type="select" label="Reported intensity values" help="[intval] See the help section below">
+                  <option value="into" selected="true">into</option>
+                  <option value="maxo">maxo</option>
+                  <option value="intb">intb</option>
+              </param>
+            </when>
+            <when value="false" />
+        </conditional>
+    </xml>
+
+    <xml name="output_peaklist"  token_function="">
+        <data name="variableMetadata" format="tabular" label="${image.name[:-6]}.@FUNCTION@.variableMetadata.tsv" from_work_dir="variableMetadata.tsv" >
+            <filter>(peaklist['peaklistBool'])</filter>
+        </data>
+        <data name="dataMatrix" format="tabular" label="${image.name[:-6]}.@FUNCTION@.dataMatrix.tsv" from_work_dir="dataMatrix.tsv" >
+            <filter>(peaklist['peaklistBool'])</filter>
+        </data>
+    </xml>
+
+    <token name="@HELP_AUTHORS@">
+.. class:: infomark
+
+**Authors**  Colin A. Smith csmith@scripps.edu, Ralf Tautenhahn rtautenh@gmail.com, Steffen Neumann sneumann@ipb-halle.de, Paul Benton hpaul.benton08@imperial.ac.uk and Christopher Conley cjconley@ucdavis.edu
+
+.. class:: infomark
+
+**Galaxy integration** ABiMS TEAM - UPMC/CNRS - Station biologique de Roscoff and Yann Guitton yann.guitton@oniris-nantes.fr - part of Workflow4Metabolomics.org [W4M]
+
+ | Contact support@workflow4metabolomics.org for any questions or concerns about the Galaxy implementation of this tool.
+
+---------------------------------------------------
+
+    </token>
+
+    <token name="@HELP_XCMS_MANUAL@">
+
+For details and explanations for all the parameters and the workflow of xcms_ package, see its manual_ and this example_
+
+.. _xcms: https://bioconductor.org/packages/release/bioc/html/xcms.html
+.. _manual: http://www.bioconductor.org/packages/release/bioc/manuals/xcms/man/xcms.pdf
+.. _example: https://bioconductor.org/packages/release/bioc/vignettes/xcms/inst/doc/xcms.html
+
+    </token>
+
+    <token name="@HELP_PEAKLIST@">
+
+Get a Peak List
+---------------
+
+If 'true', the module generates two additional files corresponding to the peak list:
+- the variable metadata file (corresponding to information about extracted ions such as mass or retention time)
+- the data matrix (corresponding to related intensities)
+
+**decimal places for [mass or retention time] values in identifiers**
+
+    | Ions' identifiers are constructed as MxxxTyyy where 'xxx' is the ion median mass and 'yyy' the ion median retention time.
+    | Two parameters are used to adjust the number of decimal places wanted in identifiers for mass and retention time respectively.
+    | Theses parameters do not affect decimal places in columns other than the identifier one.
+
+**Reported intensity values**
+
+    | This parameter determines which values should be reported as intensities in the dataMatrix table; it correspond to xcms 'intval' parameter:
+    | - into: integrated area of original (raw) peak
+    | - maxo: maximum intensity of original (raw) peak
+    | - intb: baseline corrected integrated peak area (only available if peak detection was done by ‘findPeaks.centWave’)
+
+    </token>
+
+    <xml name="citation">
+        <citations>
+            <citation type="doi">10.1021/ac051437y</citation>
+            <citation type="doi">10.1093/bioinformatics/btu813</citation>
+        </citations>
+    </xml>
+</macros>